FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2C96

2C96 - P160F

Information saved in
DME

Fault code
2C96 - P160F

Fault text
Power management, closed-circuit current violation

Fault description
Power management, closed-circuit current violation

Condition for fault identification
Test condition:
IBS detects higher standby current draw in parked phase
Terminal condition: Terminal R
Voltage condition:
none

Condition for fault memory entry
0.1 sec.

Action in service
Conduct energy diagnosis

Fault effect and breakdown warning
None
Under the worst-case scenario, high standby current draw
can discharge the battery to below the startability threshold,
resulting in a breakdown vehicle

Driver information
Warning light:
CC message 'High battery discharge when parked'

Service instruction
None