2A90
2A90 - P3018Information saved in
DME
Fault code
2A90 - P3018
Fault text
Oxygen sensor before catalytic converter, pump current
cable
Fault description
Pre-catalyst oxygen sensor, pump current cable
Condition for fault identification
Test condition:
Engine running;
Continuous lambda control enabled (B_lrs = 1)
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
3. Error paths:
1. 1.5 sec. or 1.5 sec.
2. None
3. 5 sec.
Action in service
Check wiring harness between DME and oxygen sensor in
front of catalyst; I_LSVP1
Replace oxygen sensor in front of catalyst
Fault effect and breakdown warning
It is possible to continue driving. Because the oxygen sensor
cannot be used for closed-loop control the exhaust emissions
will exceed the official limits.
MIL lights up
Higher exhaust emissions
Increased fuel consumption
Surge
Driver information
Warning light:
MIL ON
Service instruction
None