2A6D

2A6D - P3014

Information saved in
DME

Fault code
2A6D - P3014

Fault text
DME, internal fault

Fault description
DME, internal fault

Condition for fault identification
Test condition:
Engine running
Terminal condition: none
Voltage condition:
none

Condition for fault memory entry
10 sec.

Action in service
1. Clear fault memory
2. Allow vehicle to completely enter sleep mode
3. Ignition on
4. If fault is still present, replace DME

Fault effect and breakdown warning
It is possible to continue driving. Because the oxygen sensor
cannot be used for closed-loop control the exhaust emissions
will exceed the official limits.
MIL lights up
Higher exhaust emissions
Increased fuel consumption
Surge

Driver information
Warning light:
MIL ON

Service instruction