285D
285D - P101BInformation saved in
DME
Fault code
285D - P101B
Fault text
Valvetronic, adjustment range
Fault description
Valvetronic, adjustment range
Condition for fault identification
Test condition:
Control 'Initialize travel limits' must be executed
Terminal condition: Terminal 15
Voltage condition:
Voltage in onboard electrical system > 9 V
Condition for fault memory entry
none
Action in service
Perform travel limit initialization routine
Check the Valvetronic mechanism and the Valvetronic
actuator motor
Replace DME
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None