P16EB
2BD0 - P16EBInformation saved in
DME
Fault code
2BD0 - P16EB
Fault text
DME, internal fault: Watchdog output
Fault description
DME, internal malfunction: Watchdog output
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
none
Action in service
1. Clear fault memory
2. Allow vehicle to completely enter sleep mode
3. Ignition on
4. If fault is still present, replace DME
Fault effect and breakdown warning
None
none
Driver information
Warning light:
MIL ON
EML ON (CC message: ID29)
Service instruction