P160A
2C8D - P160AInformation saved in
DME
Fault code
2C8D - P160A
Fault text
Power management, battery: Exhaustive battery charge
Fault description
Power management, battery monitoring
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 30
Voltage condition:
Battery voltage measured by intelligent battery sensor <
9.52 V
Condition for fault memory entry
60S
Action in service
1. Conduct (ABL) energy diagnosis test module
2. Ask customer whether vehicle has remained parked over
an extended period
Fault effect and breakdown warning
None
- Breakdown in extreme cases
Driver information
Warning light:
none
Service instruction
None