P151B
2E42 - P151BInformation saved in
DME
Fault code
2E42 - P151B
Fault text
Intelligent battery sensor (IBS): Wake-up line, level
implausible
Fault description
Intelligent Battery Sensor, self-diagnosis 2
Condition for fault identification
Test condition:
BSD bus active
Terminal condition: Change Terminal 15
Voltage condition:
none
Condition for fault memory entry
5 sec.
Action in service
1. Check whether additional faults have been entered for
other control modules with Terminal 15 wakeup (SPEG,
DME, SZL, CAS, ABS/DSC, EPS)
2. Check TERM15/wakeup wire 15WUP for open or
intermittent open
3. With battery sensor disconnected and TERM 15 off,
check TERM15/wakeup wire 15WUP for short to positive
4. With battery sensor disconnected and TERM 15 on, check
TERM15/wakeup wire 15WUP for short to ground
5. With battery sensor connected and TERM 15 off, check
TERM15/wakeup wire 15WUP for short to positive, replace
battery sensor as indicated
6. With battery sensor connected and TERM 15 on, check
TERM15/wakeup wire 15WUP for short to ground, replace
battery sensor as indicated
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None