P1014
285A - P1014Information saved in
DME
Fault code
285A - P1014
Fault text
Valvetronic, eccentric shaft sensor: Reference
Fault description
Valvetronic, excentric shaft sensor: Reference
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
2 sec.
Action in service
If DTC 0x2856 and DTC 0x285A have been logged:
1. Check plug and wiring harness between DME and
excentric shaft sensor
2. Replace excentric shaft sensor
If DTC 0x2856 is the only one that is currently present, or it
has been logged multiple times:
1. Check wiring harness between excentric shaft sensor and
DME: CME-132(I_P_VVTDAT2S), CME-
120(O_P_VVTCS2S), CME-121(O_P_VVTCLKS)
2. Replace excentric shaft sensor
3. Replace DME
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None