P0691
2EE7 - P0691Information saved in
DME
Fault code
2EE7 - P0691
Fault text
Electric fan, activation
Fault description
Electric fan, control-activation: Short circuit to ground
Condition for fault identification
Test condition:
Output stage diagnosis
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
0.5 sec.
Action in service
1. Check wiring harness between fan and DME
2. Replace sensor
3. Replace DME
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None