2F92
2F92 - P15FCInformation saved in
DME
Fault code
2F92 - P15FC
Fault text
Engine switch-off time
Fault description
Engine switch-off time
Condition for fault identification
Test condition:
Error is recognized when divergence persists from roughly
12 to 200 sec. %(KLTEOETSTL) within one minute
between instrument cluster and DME's internal counter
while engine is running
Terminal condition: Terminal 15
Voltage condition:
0 V < electrical system voltage < 25.6 V
Condition for fault memory entry
0 sec.
Action in service
- Because this is a collateral fault, start by resolving issues
related to other faults logged in the DME or instrument
cluster; no additional action will be needed with these kinds
of faults
Fault effect and breakdown warning
None
none
Driver information
Warning light:
MIL ON (US only)
Service instruction
None