2F8B
2F8B - P15FBInformation saved in
DME
Fault code
2F8B - P15FB
Fault text
Engine switch-off time
Fault description
Engine switch-off time
Condition for fault identification
Test condition:
Error is recognized with a deviation of roughly 12 sec.
within one minute between instrument cluster and DME
internal counters while the engine is running
Terminal condition: Terminal 15
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
140 sec.
Action in service
- Because this is a collateral fault, start by resolving issues
related to other faults logged in the DME or instrument
cluster; no additional action will be needed with these kinds
of faults
Fault effect and breakdown warning
None
none
Driver information
Warning light:
MIL ON (US only)
Service instruction
None