2BD3
2BD3 - P16E8Information saved in
DME
Fault code
2BD3 - P16E8
Fault text
Monitoring, power supply 2, sensor CY320
Fault description
Monitoring, power supply 2, sensor CY320
Condition for fault identification
Test condition:
The sensor voltage supply is monitored by comparators in
the hardware. If the voltage supply is outside the switching
thresholds an error is reported. The recognition thresholds
are defined by the hardware and cannot be configured.
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
0.5 sec.
Action in service
1. Connect adapter between wiring harness and DME to
allow measurement at Pin CME-238 (DME-exhaust
camshaft sensor)
2. Measure voltage at Pin CME-238
if > 5 V -> short circuit to plus -> check wiring harness
if < 5 V -> unplug the following sensors (see causes) in
sequence and measure when the voltage at Pin CME-238
goes to 5 V then replace the affected sensor, otherwise:
- Check wiring harness
- Replace DME
if = 5 V and logged continuously, replace the DME
Fault effect and breakdown warning
None
none
Driver information
Warning light:
MIL ON
Service instruction
None