2B7B
2B7B - P1626Information saved in
DME
Fault code
2B7B - P1626
Fault text
Air mass flow sensor
Fault description
Mass airflow sensor: Fault in output stage
Condition for fault identification
Test condition:
Engine running
Terminal condition: Terminal 15
Voltage condition:
onboard electrical system voltage ubsq between 9 V and 16
V
Condition for fault memory entry
0.4 sec.
Action in service
1. Check wiring harness between DME and mass-airflow
sensor
2. Replace mass-airflow sensor
3. Replace DME
Fault effect and breakdown warning
None
none
Driver information
Warning light:
MIL ON (US only)
Service instruction
None