2B3A
2B3A - P16E6Information saved in
DME
Fault code
2B3A - P16E6
Fault text
Throttle-valve actuator, cancel adaptation due to
environmental conditions
Fault description
Throttle-valve actuator, cancel adaptation due to
environmental conditions
Condition for fault identification
Test condition:
Engine off
Terminal condition: Terminal 15
Voltage condition:
Battery voltage ub > 10 V
Condition for fault memory entry
none
Action in service
Check battery voltage (>10V), Terminal 15 off -> Terminal
15 on -> Wait 1 minute.
Provided that consistent compliance with the voltage
conditions is achieved the problem should not appear again.
Component replacement in response to this problem is not
required!
Fault effect and breakdown warning
Ability to continue driving is restricted because engine
speed is limited to roughly 1300 rpm.
No electrical current to throttle valve, EGAS limp-home
mode, rpm limit, EML on
Driver information
Warning light:
none
Service instruction
None