Manufacturer Code Charts: 2863
2863 - P1062Information saved in
DME
Fault code
2863 - P1062
Fault text
Valvetronic, power limitation
Fault description
Valvetronic, power limitation
Condition for fault identification
Test condition:
Engine running;
Valvetronic limp-home mode
At least one Valvetronic sensor signal must be present
Maximum valve stroke
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
3 sec.
Action in service
1. If other Valvetronic faults are present, then this is a
collateral error
2. Check the Valvetronic mechanism
Fault effect and breakdown warning
None
none
Driver information
Warning light:
MIL ON
EML ON (CC message: ID29)
Service instruction
None