Manufacturer Code Charts: 2860
2860 - P1077Information saved in
DME
Fault code
2860 - P1077
Fault text
Valvetronic, thermal overload protection
Fault description
Valvetronic, thermal overload protection
Condition for fault identification
Test condition:
Temperature > 175 ° at Valvetronic actuator motor
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
none
Action in service
1. If other Valvetronic faults are present, this will be a
collateral malfunction
2. Check reluctor ring to ensure that it is attached correctly.
3. If fault is still present: Replace DME.
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None