284F
284F - P1047Information saved in
DME
Fault code
284F - P1047
Fault text
Valvetronic servomotor, activation
Fault description
Valvetronic servo-motor, activation
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
0.3 sec.
Action in service
1. Check the wires to the Valvetronic servo-motor (CMI-
201(O_P_VVT1M) and/or CMI-202(O_P_VVT2M)) for
short circuit to B+. Proceed by disconnecting the VVT
motor from the wiring harness and check the harness to
determine whether battery voltage is present on one of the
pins for the Valvetronic actuator motor (ignition off)
2. If no short circuits are present in the wiring harness:
Check Valvetronic actuator motor pins for interturn short
circuit to housing
3. Replace DME
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None