Power Down Command
Power Down command
To place the vehicle in Power Down mode, it is essential for the following preconditions to be satisfied:
- DIS Tester connected
- Terminal R off (but vehicle must not have gone to sleep yet)
- Remove key
- Maximum battery voltage 12.5 V (a battery charger must not be connected)
Send the Power Down command with a suitable test module
- Disconnect OBD plug
The Power Down mode is terminated when the bus is woken.