Comparison Images EWS Oscilloscope Measurement (Functional Test)
Comparison Images EWS Oscilloscope Measurement
IMPORTANT: During the measurement, the DSC must be connected.
The speed signal from the DSC control module must be a rectangular signal with amplitude battery voltage.
The above illustration indicates a short circuit to ground.
The above illustration indicates a break in wiring and/or a problem with the DSC.