FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

67 62 ... Notes on Initializing Power Window Unit In Front Door




67 62 ... - Notes on initializing power window unit (front)





Note:
Initialization for a MINI merely involves normalization, i.e. the mechanical end stop of the power window unit is recorded and stored.
Learning the characteristic curve is not required due to the lack of an anti-trapping mechanism.
In the position





Note:
An initialization must be performed:
- in the event of malfunctions, e.g. no one-touch function or no complete closing of the door glass after closing of the door
- after disconnection of the battery negative lead
- after replacement of the flat motor/power window unit
- after work is carried out on the power window mechanism





Warning!
No anti-trapping mechanism!





Note:
Performing initialization:
- The reference point for initialization is the mechanical stop with the door closed and the window in its uppermost position
- To initialize, raise the window glass and keep the switch depressed in the Lift position for approx. 5 seconds and then release
- Checking initialization:
- Open door, window glass move down slightly
- Close door, window glass moves into "Closed" position