ECVT Automatic Transmission
Caution: Make sure all parts are absolutely clean. Seal off pipe connections with plugs. No dirt is allowed to enter the system.
Recycling:
Observe country-specific waste-disposal regulations.
Draw hydraulic fluid out of tank - do not reuse.
Install hint:
Fill hydraulic system.
Caution: Pull high voltage connector straight or damage may occur.
Release clip from intake pipe (1) on supply tank and release pipe.
Disconnect connector (1).
Disconnect high voltage connector (2).
Remove screw (1) and disconnect pressure pipe.
High pressure pipe to power pack
M8 x 1.25 x 20 Screw 10 Nm
Remove 2 bolts securing bracket to subframe.
Powerpack mounting bracket to subframe
M8 x 1.25 x 12 Screw 19 Nm
Remove nut, securing bracket to front subframe.
Powerpack mounting bracket to subframe
M8 nut 19 Nm
Remove pump assembly with connected pipe.
Remove security clip and disconnect intake pipe.