Pinpoint Test G: A Single Power Window is Inoperative- Fusion, Milan, RH Front, LH or RH Rear
Glass, Frames and Mechanisms
Pinpoint Tests
Pinpoint Test G: A Single Power Window is Inoperative- Fusion, Milan, RH Front, LH or RH Rear
Refer to Wiring Diagram Set 100, Power Windows for schematic and connector information. Diagrams By Number
Normal Operation
The RH front window control switch receives delayed accessory power from the LH front window control switch through circuit CPW14 (VT/WH) when the window lock switch is set to the UNLOCK position, and the delayed accessory feature is active. When the RH front window is operated in the up direction from the RH front window control switch, power is sent to the RH front window motor through circuit CPW20 (YE/BK) and ground through circuit CPW19 (VT). When the RH front window is operated in the down direction from the RH front window control switch, power is sent to the RH front window motor through circuit CPW19 (VT) and ground through circuit CPW20 (YE/BK).
The LH rear window control switch receives delayed accessory power from the LH front window control switch through circuit CPW14 (VT/WH) when the window lock switch is set to the UNLOCK position, and the delayed accessory feature is active. When the LH rear window is operated in the up direction from the LH rear window control switch, power is sent to the LH rear window motor through circuit CPW21 (BN) and ground through circuit CPW22 (GN/VT). When the LH rear window is operated in the down direction from the LH rear window control switch, power is sent to the LH rear window motor through circuit CPW22 (GN/VT) and ground through circuit CPW21 (BN).
The RH rear window control switch receives delayed accessory power from the LH front window control switch through circuit CPW14 (VT/WH) when the window lock switch is set to the UNLOCK position, and the delayed accessory feature is active. When the RH rear window is operated in the up direction from the RH rear window control switch, power is sent to the RH rear window motor through circuit CPW24 (WH/VT) and ground through circuit CPW23 (GY). When the RH rear window is operated in the down direction from the RH rear window control switch, power is sent to the RH rear window motor through circuit CPW23 (GY) and ground through circuit CPW24 (WH/VT).
Window Operation From LH Front Switch
When the RH front power window is operated in the up direction from the LH front window control switch, power is sent to the RH front window control switch through circuit CPW13 (GY/RD), which transfers power to the RH front window motor through circuit CPW20 (YE/BK). Ground is provided to the RH front window switch through circuit CPW12 (GN/OG), which transfers ground to the RH front window motor through circuit CPW19 (VT).
During RH front power window down operation from the LH front window control switch, power is sent to the RH front window control switch through circuit CPW12 (GN/OG), which transfers power to the RH front window motor through circuit CPW19 (VT). Ground is provided to the RH front window switch through circuit CPW13 (GY/RD), which transfers ground to the RH front window motor through circuit CPW20 (YE/BK).
When the LH rear power window is operated in the up direction from the LH front window control switch, power is sent to the LH rear window control switch through circuit CPW16 (BU/OG), which transfers power to the LH rear window motor through circuit CPW21 (BN). Ground is provided to the LH rear window switch through circuit CPW15 (YE), which transfers ground to the LH rear window motor through circuit CPW22 (GN/VT).
During LH rear power window down operation from the LH front window control switch, power is sent to the LH rear window control switch through circuit CPW15 (YE), which transfers power to the LH rear window motor through circuit CPW22 (GN/VT). Ground is provided to the LH rear window switch through circuit CPW16 (BU/OG), which transfers ground to the LH rear window motor through circuit CPW21 (BN).
When the RH rear power window is operated in the up direction from the LH front window control switch, power is sent to the RH rear window control switch through circuit CPW18 (GY/VT), which transfers power to the RH rear window motor through circuit CPW24 (WH/VT). Ground is sent to the RH rear window switch through circuit CPW17 (BN/GN), which transfers ground to the RH rear window motor through circuit CPW23 (GY).
During RH rear power window down operation from the LH front window control switch, power is sent to the RH rear window control switch through circuit CPW17 (BN/GN), which transfers power to the RH rear window motor through circuit CPW23 (GY). Ground is sent to the RH rear window switch through circuit CPW18 (GY/VT), which transfers ground to the RH rear window motor through circuit CPW24 (WH/VT).
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- LH front window switch
- RH front window switch
- Rear window motor
- Front window motor
- Rear window switch
PINPOINT TEST G: A SINGLE POWER WINDOW IS INOPERATIVE - FUSION, MILAN, RH FRONT, LH OR RH REAR
-------------------------------------------------
G1 CHECK THE VOLTAGE TO THE RH FRONT, LH REAR OR RH REAR WINDOW CONTROL SWITCH
- Disconnect: Inoperative Rear Window Control Switch C604 (RH front), C701 (LH rear) or C819 (RH rear).
- Ignition ON.
- NOTE: Set the LH front window lock switch to the UNLOCK position.
- Measure the voltage between the inoperative rear window connector and ground:
- for the RH front window control switch, measure the voltage between RH front window control switch C604-3, circuit CPW14 (VT/WH), harness side and ground.
- for the RH rear window control switch, measure the voltage between RH rear window control switch C819-3, circuit CPW14 (VT/WH), harness side and ground.
- for the LH rear window control switch, measure the voltage between C701-3, circuit CPW14 (VT/WH), harness side and ground.
- Is the voltage greater than 10 volts?
Yes
GO to G3.
No
GO to G2.
-------------------------------------------------
G2 CHECK FOR OPEN IN CIRCUIT CPW14 (VT/WH)
- Disconnect: LH Front Window Control Switch C537B.
- Ignition OFF.
- Measure the resistance between the inoperative rear window connector and the LH front window control switch connector:
- for the RH front window control switch, measure the resistance between RH front window control switch C604-3, circuit CPW14 (VT/WH), harness side and LH front window control switch C537B-2, circuit CPW14 (VT/WH), harness side.
- for the RH rear window control switch, measure the resistance between RH rear window control switch C819-3, circuit CPW14 (VT/WH), harness side and LH front window control switch C537B-2, circuit CPW14 (VT/WH), harness side.
- for the LH rear window control switch, measure the resistance between LH rear window control switch C701-3, circuit CPW14 (VT/WH), harness side and LH front window control switch C537B-2, circuit CPW14 (VT/WH), harness side.
- Is the resistance less than 5 ohms?
Yes
INSTALL a new LH front window control switch. REFER to Window Control Switch Service and Repair. TEST the system for normal operation.
No
REPAIR the circuit. TEST the system for normal operation.
-------------------------------------------------
G3 CHECK THE GROUNDS TO THE INOPERATIVE REAR WINDOW CONTROL SWITCH
- Ignition OFF.
- Measure the resistance between the inoperative window control switch and ground:
- for the RH front window control switch, measure the resistance between RH front window control switch C604-1, circuit CPW12 (GN/OG), harness side and ground; and between RH front window control switch C604-6, circuit CPW13 (GY/RD), harness side and ground.
- for the RH rear window control switch, measure the resistance between RH rear window control switch C819-1, circuit CPW17 (BN/GN), harness side and ground; and between RH rear window control switch C819-6, circuit CPW18 (GY/VT), harness side and ground.
- for the LH rear window control switch, measure the resistance between LH rear window control switch C701-1, circuit CPW15 (YE), harness side and ground; and between LH rear window control switch C701-6, circuit CPW16 (BU/OG), harness side and ground.
- Are the resistances less than 5 ohms?
Yes
GO to G5.
No
GO to G4.
-------------------------------------------------
G4 CHECK THE CIRCUITS TO THE INOPERATIVE REAR WINDOW CONTROL SWITCH FOR AN OPEN
- Ignition OFF.
- Disconnect: LH Front Window Control Switch C537A and C537B.
- For an inoperative RH front power window, measure the resistance between LH front window control switch C537A-3, circuit CPW12 (GN/OG) and RH front window control switch C604-1, circuit CPW12 (GN/OG), harness side; and between LH front window control switch C537A-8, circuit CPW13 (GY/RD) and RH front window control switch C604-6, circuit CPW13 (GY/RD), harness side.
- For an inoperative LH rear power window, measure the resistance between LH front window control switch C537B-1, circuit CPW15 (YE) and LH rear window control switch C701-1, circuit CPW15 (YE), harness side; and between LH front window control switch C537B-6, circuit CPW16 (BU/OG) and LH rear window control switch C701-6, circuit CPW16 (BU/OG), harness side.
- For an inoperative RH rear power window, measure the resistance between LH front window control switch C537B-4, circuit CPW17 (BN/GN) and RH window control switch C819-1, circuit CPW17 (BN/GN), harness side; and between LH front window control switch C537B-8, circuit CPW18 (GY/VT) and RH rear window control switch C819-6, circuit CPW18 (GY/VT), harness side.
- Are the resistances less than 5 ohms?
Yes
INSTALL a new LH front window control switch. REFER to Window Control Switch Service and Repair. TEST the system for normal operation.
No
REPAIR the circuit(s) for an open. TEST the system for normal operation.
-------------------------------------------------
G5 CHECK THE INOPERATIVE WINDOW CONTROL SWITCH
- Ignition ON.
- For an inoperative RH front window, connect a fused jumper wire between RH front window control switch C604-2, circuit CPW19 (VT), harness side and RH front window control switch C604-3, circuit CPW14 (VT/WH), harness side; and between RH front window control switch C604-5, circuit CPW20 (YE/BK), harness side and RH front window control switch C604-6, circuit CPW13 (GY/RD), harness side. The RH front window should operate in the downward direction.
- For an inoperative LH rear window, connect a fused jumper wire between LH rear window control switch C701-2, circuit CPW22 (GN/VT), harness side and LH rear window control switch C701-3, circuit CPW14 (VT/WH), harness side; and between LH rear window control switch C701-5, circuit CPW21 (BN), harness side and LH rear window control switch C701-6, circuit CPW16 (BU/OG), harness side. The LH rear window should operate in the downward direction.
- For an inoperative RH rear window, connect a fused jumper wire between RH rear window control switch C819-2, circuit CPW23 (GY), harness side and RH rear window control switch C819-3, circuit CPW14 (VT/WH), harness side; and between RH rear window control switch C819-5, circuit CPW24 (WH/VT), harness side and RH rear window control switch C819-6, circuit CPW18 (GY/VT), harness side. The RH rear window should operate in the downward direction.
- For an inoperative RH front window, connect a fused jumper wire between RH front window control switch C604-2, circuit CPW19 (VT), harness side and RH front window control switch C604-1, circuit CPW12 (GN/OG), harness side; and between RH front window control switch C604-5, circuit CPW20 (YE/BK), harness side and RH front window control switch C604-3, circuit CPW14 (VT/WH), harness side. The RH front window should operate in the upward direction.
- For an inoperative LH rear window, connect a fused jumper wire between LH rear window control switch C701-2, circuit CPW22 (GN/VT), harness side and LH rear window control switch C701-1, circuit CPW15 (YE), harness side; and between LH rear window control switch C701-5, circuit CPW21 (BN), harness side and LH rear window control switch C701-3, circuit CPW14 (VT/WH), harness side. The LH rear window should operate in the upward direction.
- For an inoperative RH rear window, connect a fused jumper wire between RH rear window control switch C819-2, circuit CPW22 (GN/VT), harness side and RH rear window control switch C819-1, circuit CPW17 (BN/GN), harness side; and between RH rear window control switch C819-5, circuit CPW24 (WH/VT), harness side and RH rear window control switch C819-3, circuit CPW14 (VT/WH), harness side. The RH rear window should operate in the upward direction.
- Did the inoperative window operate correctly?
Yes
INSTALL a new LH or RH rear window control switch. REFER to Window Control Switch Service and Repair. TEST the system for normal operation.
No
GO to G6.
-------------------------------------------------
G6 CHECK THE POWER WINDOW MOTOR CIRCUITS
- Ignition OFF.
- Disconnect: Inoperative Window Motor C608 (RH front), C726 (LH rear) or C828 (RH rear).
- For an inoperative RH front window, measure the resistance between RH front window control switch C604-2, circuit CPW19 (VT), harness side and RH front window motor C608-2, circuit CPW19 (VT), harness side.
- For an inoperative LH rear window, measure the resistance between LH rear window control switch C701-2, circuit CPW22 (GN/VT), harness side and LH rear window motor C726-2, circuit CPW22 (GN/VT), harness side.
- For an inoperative RH rear window, measure the resistance between RH rear window control switch C819-2, circuit CPW23 (GY), harness side and RH rear window motor C828-2, circuit CPW23 (GY), harness side.
- For an inoperative RH front window, measure the resistance between RH front window control switch C604-5, circuit CPW20 (YE/BK), harness side and RH front window motor C608-1, circuit CPW20 (YE/BK), harness side.
- For an inoperative LH rear window, measure the resistance between LH rear window control switch C701-5, circuit CPW21 (BN), harness side and LH rear window motor C726-1, circuit CPW21 (BN), harness side.
- For an inoperative RH rear window, measure the resistance between RH rear window control switch C819-5, circuit CPW24 (WH/VT), harness side and RH rear window motor C726-1, circuit CPW24 (WH/VT), harness side.
- Are the resistances less than 5 ohms?
Yes
INSTALL a new RH front, LH or RH rear window motor. REFER to Window Regulator Motor Window Regulator Motor. TEST the system for normal operation.
No
REPAIR the circuit. TEST the system for normal operation.
-------------------------------------------------