FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Pinpoint Test M: An Individual Button/Feature Is Inoperative From The Remote Keyless Entry (RKE) Transmitter




Locks, Latches and Entry Systems

Pinpoint Tests

Pinpoint Test M: An Individual Button/Feature Is Inoperative From The Remote Keyless Entry (RKE) Transmitter

Normal Operation

When any Integrated Keyhead Transmitter (IKT) button is pressed, the SJB receives and processes the command to provide the appropriate output.

This pinpoint test is intended to diagnose the following:

- Door locks
- Horn system
- Luggage compartment lid release
- Turn signal system
- IKT



PINPOINT TEST M: AN INDIVIDUAL BUTTON/FEATURE IS INOPERATIVE FROM THE RKE TRANSMITTER

NOTE: The panic feature will only operate when the key is in the OFF or LOCK positions.

-------------------------------------------------
M1 VERIFY THE DOOR LOCK OPERATION


- Press the lock and unlock button on the driver door lock control switch while observing the door lock operation.
- Do the door locks operate correctly?

Yes
GO to M2.

No
GO to Symptom Chart. Symptom Related Diagnostic Procedures

-------------------------------------------------
M2 VERIFY THE HORN OPERATION


- Enter the following diagnostic mode on the scan tool: SJB DataLogger.
- Select the SJB PID (HORNRLY) and active command the horn on.
- Does the horn sound when commanded on?

Yes
GO to M3.

No
REFER to Horn.

-------------------------------------------------
M3 VERIFY THE HAZARD LAMP OPERATION


- Place the hazard switch in the ON position.
- Do the hazard lamps operate correctly?

Yes
GO to M4.

No
REFER to Lighting and Horns. Lighting and Horns

-------------------------------------------------
M4 VERIFY THE LUGGAGE COMPARTMENT LID RELEASE OPERATION


- Press the luggage compartment lid release button, located next to the headlamp switch.
- Does the luggage compartment lid release?

Yes
REPLACE the inoperative IKT and PROGRAM all of the IKTs. REFER to Antitheft and Alarm Systems. INFORM the customer that any IKTs not present need to be programmed. TEST the system for normal operation.

No
GO to Symptom Chart. Symptom Related Diagnostic Procedures

-------------------------------------------------