Inspection and Verification
INSPECTION AND VERIFICATION1. Verify the customer concern by operating the system.
2. Visually inspect for obvious signs of mechanical or electrical damage.
Visual Inspection Chart:
3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
4. If the concern is not visually evident, determine the symptom. GO to Symptom Chart - Roof Opening Panel or GO to Symptom Chart - Noise, Vibration and Harshness (NVH). Symptom Chart - Roof Opening Panel Symptom Chart - Noise, Vibration and Harshness (NVH)