Expansion Valve: Description and Operation
Thermostatic Expansion Valve (TXV)The TXV is located between the evaporator core and the TXV manifold and tube assembly at the rear of the engine compartment. The TXV provides a restriction to the flow of refrigerant from the high-pressure side of the refrigerant system and separates the low-pressure and high-pressure sides of the refrigerant system. Refrigerant entering and exiting the evaporator core passes through the TXV through 2 separate flow paths. An internal temperature sensing bulb senses the temperature of the refrigerant flowing out of the evaporator core and adjusts an internal pin-type valve to meter the refrigerant flow into the evaporator core. The internal pin-type valve decreases the amount of refrigerant entering the evaporator core at lower temperatures and increases the amount of refrigerant entering the evaporator core at higher temperatures.
A/C Pressure Transducer
The A/C pressure transducer monitors the compressor discharge pressure and communicates with the PCM. The PCM will interrupt A/C compressor operation in the event that the A/C pressure transducer indicates high system discharge pressures. It is also used to sense low charge conditions. If the pressure is below a predetermined value for a given ambient temperature, the PCM will not allow the clutch to engage.
The A/C pressure transducer is located on the compressor-to-condenser discharge line near the condenser inlet fitting. It is not necessary to recover the refrigerant before removing the A/C pressure transducer.