Roof Opening Panel Glass
ROOF OPENING PANEL GLASSExploded View
1. Open the roof opening panel to the VENT position.
2. Remove the 4 roof opening panel glass screws.
- To access the glass screws, unclip the top portion of the concertina blind and position aside as shown.
- To install, tighten to 6 Nm (53 lb-in).
3. To install, reverse the removal procedure.
- Verify that the roof opening panel is centered and aligned before tightening the screws. For additional information, refer Roof Opening Panel Alignment. Roof Opening Panel Alignment
- Initialize the roof opening panel motor. For additional information, refer to Roof Opening Panel Motor Initialization. Programming and Relearning