Air Cleaner Housing: Service and Repair
AIR CLEANERExploded View
Removal and Installation
1. Disconnect the mass air flow (MAF) sensor electrical connector.
2. Loosen the clamp and disconnect the air cleaner outlet pipe from the air cleaner cover.
- To install, tighten to 4 Nm (35 lb-in).
3. Remove the 3 nuts and the engine air cleaner assembly.
- To install, tighten to 6 Nm (53 lb-in).
4. To install, reverse the removal procedure.