Neutral Position Learning
Neutral Position LearningSpecial Tools:
NOTE: When installing a new transmission control module, the initialized learned values will need to be carried out.
1. With the vehicle in NEUTRAL, position it on a hoist.
2. Install the scan tool.
3. Turn the ignition ON.
4. The scan tool should indicate NEUTRAL.
- If the scan tool does not indicate NEUTRAL, carry out transmission control module (TCM) adjustment.
5. If NEUTRAL is indicated on the scan tool, move the shift lever to PARK and turn the ignition OFF.
6. Turn the ignition ON and move the shift lever from PARK to DRIVE.
- The scan tool should indicate each PRNDL position.
7. If the diagnostic display indicates each PRNDL position, check for any DTC codes.
8. If the diagnostic display does not indicate each PRNDL position, carry out Transmission Control Module (TCM) Initial Learning.