Test F: DTCs B299C and B29A6 - Suppressor Left/Right Circuit Short to Ground - Loop #1
PINPOINT TEST F: DTCs B299C AND B29A6 - SUPPRESSOR LEFT/RIGHT CIRCUIT SHORT TO GROUND - LOOP #1F1-F2:
F2-F5:
Normal Operation
The fire suppression module checks all of the fire suppressor circuits for faults. If the fire suppression module detects a short to ground on the LH fire suppressor squib 1 circuits, it stores DTC B299C in memory and illuminates the fire suppression system indicator. If the fire suppression module detects a short to ground on the RH fire suppressor squib 1 circuits, it stores DTC B29A6 in memory and illuminates the fire suppression system indicator.
Possible Causes
- Circuit 2310 (OG) short to ground
- Circuit 2311 (DG) short to ground
- Circuit 2312 (LG) short to ground
- Circuit 2313 (BK/WH) short to ground
- LH fire suppressor
- RH fire suppressor
- Fire suppression module