Programming and Relearning
ROOF OPENING PANEL MOTOR INITIALIZATIONCAUTION: Make sure there are no obstructions present in the roof opening panel when carrying out this procedure. Any obstructions may damage the roof opening panel assembly.
NOTE:
- A new roof opening panel motor must be initialized after installation. The panel only moves towards the full-open position if in the slide range until initialized.
- This procedure must be carried out when repairs are made on any part of the roof opening panel system. This includes when a new roof opening panel motor is installed, or a new mechanical roof opening panel assembly is installed.
1. If required, connect the overhead console wiring harness electrical connector to enable the use of the roof opening panel switch.
2. Turn the ignition lock cylinder to the RUN position.
3. If a new roof opening panel motor was installed, press and hold the open switch while the roof opening panel opens past the full-open position and suddenly back to the complete full-open position.
4. If a new roof opening panel motor was not installed, use the roof opening panel switch to open the roof opening panel to the full-open position. Then press and hold the switch (for approximately 10 seconds) until the roof opening panel moves past full-open and suddenly back to the complete full-open position.
5. Release the roof opening panel switch and test the system for normal operation by checking the one-touch open, close, and tilt operations.