Test I: The Illuminated Entry Is Inoperative When Using The Remote Transmitter/Keypad
PINPOINT TEST I: THE ILLUMINATED ENTRY IS INOPERATIVE WHEN USING THE REMOTE TRANSMITTER/KEYPADI1-I3:
Normal Operation
When the unlock button is pressed on the remote keyless entry (RKE) transmitter, or the unlock code is entered on the remote keypad, a signal is sent to the smart junction box (SJB). The SJB then activates the courtesy lamp relay, which when activated supplies voltage to the interior lamps.
Possible Causes
- RKE system
- SJB