Manifold Pressure/Vacuum Sensor: Service and Repair
MANIFOLD ABSOLUTE PRESSURE (MAP) SENSORRemoval and Installation
1. Disconnect the battery ground cable.
2. Disconnect the manifold absolute pressure (MAP) sensor electrical connector.
3. Remove the bolt and the MAP sensor.
- To install, tighten to 6 Nm (53 lb-in).
- When installing the sensor, if the bolt fails to hold specified torque, relocate the sensor and retain, using the auxiliary bolt hole in the intake manifold.
4. NOTE: Clean and inspect the sealing surface.
To install, reverse the removal procedure.