Test G: The EATC System Is Inoperative, Intermittent or Incorrect Operation
PINPOINT TEST G: THE EATC SYSTEM IS INOPERATIVE, INTERMITTENT OR INCORRECT OPERATIONG1-G7:
G8-G13:
G13 Continued:
Normal Operation
Under normal operation, the EATC module receives a ground through circuit GD116 (BK/VT). The EATC module is supplied constant battery voltage through circuit SBP07 (WH/RD) and ignition switched voltage through circuit CBP20 (YE/VT).
NOTE: For a complete explanation of the EATC system functions, refer to Description and Operation.
Possible Causes
- Fuse(s)
- An open in circuit GD116 (BK/VT), SBP07 (WH/RD) or CBP20 (YE/VT)
- EATC module