Test A: The Control Illumination Is Inoperative
PINPOINT TEST A: THE CONTROL ILLUMINATION IS INOPERATIVEA1-A3:
A3-A4:
Normal Operation
The lighting control module (LCM) receives voltage from the central junction box (CJB) on circuit 54 (LG/YE). With the parking lamps on, the LCM generates a variable pulse width modulated (PWM) voltage which is distributed to the dimmable components on circuit 484 (OG/BK). Light intensity is adjusted by rotating the instrument panel dimmer switch.
Possible Causes
- Fuse(s)
- circuit 54 (LG/YE) open
- circuit 484 (OG/BK) open or short to ground
- circuit 676 (PK/OG) open
- LCM