Test A: All The Power Windows Are Inoperable
PINPOINT TEST A: ALL THE POWER WINDOWS ARE INOPERABLEA1:
A1-A3:
A3-A4:
A5-A6:
Normal Operation
With the key in the ACC or RUN position the voltage is supplied to the coil side of the accessory delay relay through circuit 297 (LB/PK). When the accessory delay relay is energized, battery voltage is supplied to the driver window control switch on circuit 193 (YE/LG). The driver window control switch provides voltage and ground to all other window control switches. The driver window control switch is grounded through circuit 57 (BK).
Possible Causes
- fuse(s)
- circuit breaker
- circuit 57 (BK) open
- circuit 193 (YE/LG) open or short to ground
- circuit 297 (LB/PK) open
- circuit 768 (BN/YE) open
- accessory delay relay
- driver window control switch