Alternator: Service and Repair
REMOVAL1. Disconnect the battery.
2. Release the tension and remove the accessory drive belt from the generator pulley.
3. Remove the pin-type retainer and release the wiring harness from the generator bracket.
4. Remove the nut and disconnect the generator electrical connectors.
^ Position the cover aside.
5. Remove the bolts and the generator bracket.
6. Loosen the bolts and remove the generator.
INSTALLATION
1. To install, reverse the removal procedure.