Reactivation Procedures
WARNING: THE AIR BAG RESTRAINT SYSTEM DIAGNOSTIC TOOLS MUST BE REMOVED AND THE AIR BAG MODULES RECONNECTED WHEN THE SYSTEM IS REACTIVATED TO AVOID NON-DEPLOYMENT IN A COLLISION, RESULTING IN POSSIBLE PERSONAL INJURY.1. Disconnect the battery ground cable.
2. Wait at least one minute for the backup power supply in the Restraints Control Module (RCM) to deplete its stored energy.
3. Remove the restraint system diagnostic tool from the driver safety belt retractor and pretensioner electrical connector.
4. Connect the driver safety belt retractor and pretensioner electrical connector.
5. Remove the restraint system diagnostic tool from the passenger safety belt retractor and pretensioner electrical connector.
6. Connect the passenger safety belt retractor and pretensioner electrical connector.
7. Remove the restraint system diagnostic tools from the passenger air bag module electrical connectors.
8. Install the passenger air bag module electrical connector.
9. Remove the restraint system diagnostic tools from the driver air bag module electrical connectors.
10. Install the driver air bag module.
11. Reconnect the battery ground cable.
12. Prove out the system.