Attachment III - Technical Information
SERVICE PROCEDURE1. Reprogram the PCM to the latest calibration level. Use one (1) of the following two (2) methods:
^ Worldwide Diagnostic System (WDS), with software level B13.7 or later.
^ New Generation STAR (NGS) Tester with Rotunda Flash Cable (007-00531) and Rotunda Flash Card (007-00532). The calibration must be downloaded to a flash card using WDS with software level B13.7 or later.
PREPARE AUTHORIZED MODIFICATIONS LABEL
1. Obtain and prepare the Authorized Modifications Label. Write the modification completed, your P&A Code, date of repair and the recall program type and program number. See Figure 1.
2. Clean an area on the upper radiator support.
3. Apply the label to this clean area.
4. Provide California and Massachusetts owners with a "Vehicle Emission Recall-Proof of Correction" certificate.