Shift Solenoid Diagnostics
Solenoid Operation Chart-CD4E
Shift Solenoid Failure Mode Chart "Always Off"
Failed OFF due to PCM and/or vehicle wiring concerns, and/or solenoid electrically stuck off, and/or hydraulically or mechanically stuck off.
Shift Solenoid Failure Mode Chart "Always On"
Failed ON due to PCM and/or vehicle wiring concerns, and/or solenoid electrically stuck on, and/or hydraulically or mechanically stuck on.