Initial Inspection and Diagnostic Overview
1. Verify the customer concern by operating the Daytime Running Lamps (DRL) system.2. Visually inspect the system for obvious signs of electrical damage.
VISUAL INSPECTION CHART
Electrical
^ Lamps.
^ Fuse 23 (15 A).
^ Connectors.
^ Circuit open/shorted.
^ Ignition switch.
^ Headlamp switch.
^ DRL relay.
^ Multi - function switch.
3. If the concern is not visually evident, determine the symptom and proceed to the Symptom Chart. Symptom Related Diagnostic Procedures