Initial Inspection and Diagnostic Overview
1. Verify the customer concern by operating the system.2. Visually inspect for obvious signs of mechanical and electrical damage.
VISUAL INSPECTION CHART
Mechanical
^ Misaligned or damaged Digital Transmission Range (DTR) sensor
Electrical
^ Blown Central Junction Box (CJB) Fuse 5 (15 A)
^ Damaged wiring harness
^ Loose or corroded connection
^ Damaged bulb(s)
^ Damaged DTR sensor
3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
4. If the concern is not visually evident, verify the symptom and refer to the Symptom Chart to continue diagnostics. Symptom Related Diagnostic Procedures