AX4N
1. Conduct backflushing with a Rotunda Torque Converter Cleaner 014-002E or equivalent. Test your equipment to make sure that a vigorous fluid flow is present before proceeding. Replace the system filter if flow is weak or contaminated.2. To aid in attaching the cleaner to the transmission steel cooler tubes, connect two additional rubber hoses to the transmission end of the steel transmission cooler tubes as described below.
a. Connect the cleaner tank pressure line to the steel transmission cooler return tube.
b. Connect a tank return haw to the steel transmission cooler pressure tube. Place the outlet end of this hose in the solvent tank reservoir.
3. Turn on solvent pump and allow the solvent to circulate a minimum of five minutes (cycling switch on and off will help dislodge contaminants in cooler system).
4. Switch off the solvent pump and disconnect the solvent pressure hose from the transmission cooler return tube.
5. Use compressed air to blow out the cooler(s) and tubes (blow air into the transmission cooler return tube) until all solvent is removed.
Cooler Lines:
6. Remove the rubber return hose from the remaining steel cooler tube.