AX4N
Tool Installation:
1. Position End Play Checking Tool T80L-7902-A and Converter Guide Sleeve T86P-7902-A in torque converter hub.
2. Tighten nut on checking tool.
Torque Converter Endplay Test:
3. Mount Dial Indicator with Bracketry TOOL-4201-C or equivalent on end play checking tool.
With stylus contacting converter shell and with indicator at zero, lift on checking tool handles.
If indicator reading is above 1.27 mm (0.050 inch), replace the torque converter.