Lifter / Lash Adjuster, Valve
GENERAL SPECIFICATIONSValve Tappet, Hydraulic
Diameter (STD) 22.206 mm (0.874 in)
Clearance to Bore 0.018-0.069 mm (0.0007-0.0027 in)
Service Limit 0.127 mm (0.005 in)
Hydraulic Leakdown Rate (a)
Collapsed Tappet Gap (Nominal)
Intake and Exhaust 2.15-4.69 mm (0.085-0.185 in)
TORQUE SPECIFICATIONS
Tappet Guide Plate to Cylinder Block Bolts 10-14 Nm (89-123 inch. lbs.)
(a) 20-200 seconds to leakdown 3.18 mm (0.125 in) with 225 Newtons (50 pounds) load and tappet filled with leak-down fluid.