Inspection and Verification (Start Testing Here)
1. Verify the customer concern by operating the turn signal lamps.2. Visually inspect for obvious signs of mechanical and electrical damage.
VISUAL INSPECTION CHART
Mechanical
- Damaged components
Electrical
- Blown fuse(s):
- 10A METER or 15A METER (wagon only)
- 15A HAZARD
- Damaged wiring harness
- Loose, damaged, or corroded connectors
- Blown bulbs
3. If the fault is not visually evident, verify the symptom and refer to the Symptom Chart. [1][2]Symptom Chart(s)