Instrument Cluster and Panel Lights
1. Verify the customer's concern.2. Visually inspect for obvious signs of mechanical and electrical damage.
Mechanical
^ Stuck or binding light switch rheostat resistor.
Electrical
^ Blown fuse:
- 10A TAIL (wagons only)
- 15A TAIL
^ Loose or corroded connections.
^ Damaged wiring harness.
^ Damaged light switch rheostat resistor.
^ Damaged TAIL relay.
^ Damaged or loose lamp(s).
3. If the fault is not visually evident, verify the symptom and refer to the Symptom Chart. Symptom Related Diagnostic Procedures