Resistance/Continuity test
CAUTION: For resistance checks be sure that the LARGE DIAL is set to TR/MLP SENSOR TEST or damage to the ohmmeter could result.1. Using a digital volt-ohmmeter and the transmission tester, perform Pinpoint Test D or Transaxle Reference Manual based on the DTC displayed.
2. Perform repairs as indicated by the pinpoint test. Always erase all codes, retest and road test vehicle after a repair.
3. Set ohmmeter to 1000 ohms.
4. Connect ohmmeter COM jack to SIG RTN jack.
5. Connect ohmmeter POS lead to TR jack. LED turns OFF when circuit is open.
6. Record resistance in every gear position while moving the shift lever to each position.
7. Refer to the following list:
Shift Lever Position: Min-Max Resistance (Ohms)
PARK: 3770-4607 Ohms
REVERSE: 1304-1593 Ohms
NEUTRAL: 660-806 Ohms
OVERDRIVE: 361-442 Ohms
SECOND/DRIVE*: 190-232 Ohms
FIRST: 78-95 Ohms
* Same values for SECOND (electronic transaxle with separate positions for DRIVE and OVERDRIVE).
8. If values are out of range, refer to Pinpoint Test D.