Positive Crankcase Ventilation Valve: Service and Repair
PCV Valve And Related Components:
REMOVAL and INSTALLATION
1. Remove air cleaner outlet tube.
2. Disconnect crankcase vent connector and hose from Positive Crankcase Ventilation (PCV) valve.
3. Remove valve from grommet in valve cover.
4. Inspect valve and grommet for deterioration. Replace if necessary.
5. To install, reverse removal procedure.