Test Notes
NORMAL OPERATIONThe air bag diagnostic monitor measures the resistance between the ground connection at its bracket and the reference ground at Pin C277-18, Circuit 57 (BK). If the air bag diagnostic monitor measures a difference of more than 3.0 ohms between the ground at Pin C277-18, Circuit 57 (BK) and the ground at its bracket, the air bag diagnostic monitor will store in memory DTC B1921 and flash lamp fault code 21 on the AIR BAG indicator. Should the difference in resistance between Pins C277-18, Circuit 57 (BK) and air bag diagnostic monitor bracket ground be serviced or otherwise reduced to less than 3.0 ohms, the air bag diagnostic monitor will store a DTC B1921 in memory.
POSSIBLE CAUSES
A high resistance reading at the air bag diagnostic monitor bracket ground can be caused by:
- a poor attachment of the air bag diagnostic monitor due to loose mounting, dirt or corrosion at the air bag diagnostic monitor bracket mounting surface(s).
- a poor reference ground at Pins C276-10 and C277-18, Circuit 57 (BK) of the air bag diagnostic monitor.