Master Power Window Switch
NOTE: Use an ohmmeter such as Rotunda Digital Volt-Ohmmeter 014-00407 or equivalent to test the power window switch.The LH window regulator control switch is provided B+ through Pin C1-5. Ground is provided through Pins C1-1, C1-6, C1-7.
- With window regulator control switch in NEUTRAL position, resistance should be less than 5 ohms between Pins C1-1 and C1-4 and C1-2 and C1-6.
- With window regulator control switch in LH up position, resistance should be less than 5 ohms between Pins C1-5 and C1-4 and C1-6 and C1-2.
- With window regulator control switch in LH down position, resistance should be less than 5 ohms between Pins C1-2 and C1-5 and C1-1 and C1-4.
- With window regulator control switch in RH up position, resistance should be less than 5 ohms between Pins C2-2, C2-3, C2-5 and C2-7.
- With window regulator control switch in RH down position, resistance should be less than 5 ohms between Pins C2-6 and C2-3 and C2-5 and C2-2.
If window regulator control switch does not test replace the window regulator control switch.